Cisco Catalyst 5000


Product Overview

Cisco"s Catalyst 5000 Family which consists of the 5500 Series and the 5000 Series offers switching solutions focused on the needs of high performance wiring closets for large enterprises. The 5000 Family is also well suited for small and mid-range enterprise backbones. The Cisco Catalyst 5000 Family of switches is based upon proven Cisco switching technology that is being used in the largest campus networks in the world.

With integrated frame and cell switching, full support for Cisco IOS-based routing, full support for Fast EtherChannel, Gigabit EtherChannel, and ATM, the Catalyst 5000 Family is well positioned to evolve as campus bandwidth needs grow. Furthermore, the Catalyst 5000 Family supports data communication between any type of media.The media-independent architecture supports all legacy LAN and Asynchronous Transfer Mode (ATM) switching technologies through a wide range of Ethernet, Fast Ethernet, Gigabit Ethernet, Fiber Distributed Data Interface (FDDI), Token Ring, and ATM switch modules.

All Catalyst 5000 Family switches support NetFlow switching as part of the architecture. NetFlow switching combines the simplicity and speed of switching with the intelligence and scalability of routing. This feature enables multilayer switching scalability. A route-switch module (RSM) delivers integrated support for Cisco IOS-based multiprotocol routing, and a NetFlow switching feature card option on Supervisor Engine III scales forwarding capacity to millions of packets per second.

Cisco"s Catalyst 5000 Family features five modular chassis: 2-, 5-, 9-, and 13-slot versions. All five chassis share the same set of interface modules and software features, providing scalability while maintaining interoperability and investment protection across all chassis.

The Cisco Catalyst 5000 Family consists of the following multilayer switching systems:

Key Features and Benefits

The Catalyst 5000 Family of multilayer switching systems includes the following standard features and options:


Note Modular 2-, 5-, 9-, or 13-slot chassis base chassis does not ship with any modules; these must be ordered separately


Figure 7-1: Catalyst 5000 Rear View With AC Power Supplies

Figure 7-2: Catalyst 5000 Rear View With DC Power Supplies

Figure 7-3: Catalyst 5002 Rear View

The following figure shows a rear view of the Catalyst 5500 13-slot chassis with two supervisor engine IIs installed in slots 1 and 2, and an ATM Switch Processor (ASP) module installed in slot 13 with four port adapter modules (PAMs) installed above it.

Figure 7-4: Catalyst 5500 Rear View

Figure 7-5: Catalyst 5505 Rear View

Specifications

Hardware

The following abbreviations are used in the tables in this section.

 

Table 7-3: Catalyst 5000 Family Summary of Features

Characteristic Description
Placement Rack-mounted, front or back (standard 19-inch rack)

Center-mount for 23" two post racks available for 5500/5509/5505/5000 chassis

Switching backplane 1.2 Gbps (Catalyst 5000 and 5002): Supports over 1 million pps

3.6 Gbps (Catalyst 5500/5509/5505)

Memory 4-MB Flash memory (all supervisor engine I models)

8-MB Flash memory (all supervisor engine II models)

8-MB Flash memory + PC Card Flash support (all supervisor engine III models)

16-MB DRAM (supervisor engine II)

4-MB or 20-MB DRAM (supervisor engine I)

16-MB DRAM (supervisor engine II)

32-MB DRAM (supervisor engine III)

128-KB NVRAM (supervisor engine I)

256-KB NVRAM (supervisor engine II and III)

Interfaces Supervisor Engine I console: DB-25 (female)

Supervisor Engine II console: DB-25 (female)

Supervisor Engine III console: RJ-45 (female)

Supervisor Engine I 100BaseTX uplink: RJ-45 (female), 2 interfaces

Supervisor Engine I 100BaseFX uplink: MMF SC or SMF SC, 2 interfaces

Supervisor Engine II 100 BaseTXuplink: RJ-45 (female), MII

Supervisor Engine II 100 BaseFXuplink: MMF SC, SMF SC

Supervisor Engine III 10/100Base TX uplink: RJ-45 (female), 2 interfaces

Supervisor Engine III 10/100Base TX uplink: RJ-45 (female), 4 interfaces

Supervisor Engine III 100BaseFX uplink: MMF SC or SMF SC, 2 interfaces

Supervisor Engine III 1000BaseSX uplink: MMF SC, 2 interfaces

Supervisor Engine III 1000BaseLX uplink: SMF SC, 2 interfaces

Group Switched 10BaseT: RJ-21 (female), 48 interfaces

Switched 10BaseT: RJ-21 (female), 48 or 24 interfaces

Switched 10BaseT: RJ-45 (female), 24 interfaces

Switched 10BaseFL: SC (female), 12 interfaces

Group Switched 100BaseTX: RJ-45 (female), 24 interfaces

Switched 10/100BaseTX: RJ-45 (female), 24 or 12 interfaces

Switched 100BaseFX: MMF SC, 12 interfaces

Switched 100BaseFX: MMF SC, SMF SC, 12 interfaces (6 MMF interfaces plus 6 SMF interfaces)

Fast Ether Channel 10/100BaseTX: RJ-45 (female), 24 or 12 interfaces

Fast Ether Channel 100BaseFX: MMF SC, 12 interfaces

Gigabit Ethernet: GBIC SX or LX, 3 interfaces

Gigabit EtherChannel: GBIC SX or LX, 9 interfaces

Switched Token Ring: RJ-45 copper UTP/STP (female), 16 ports

Switched Token Ring: MMF 62.5-micron fiber, 16 ports

ATM LANE/MPOA Uplink: OC-3 or OC-12: SMF SC, or MMF SC, 1 interface (dual-PHY)

ATM LAN Emulation: UTP RJ-45, MMF SC, SMF SC, dual PHY

CDDI: RJ-45 (female), 1 interface

FDDI: MMF MIC, SMF ST, 1 interface

Optical bypass switch connector: 6-pin mini-DIN

Port adapter modules (for Catalyst 5500) ATM OC-3: SONET STS3c/SDH STM1, MMF SC or SMF SC, RJ-45, 4 ports

ATM OC-12: SONET STS12c/STM4c, SMF SC, 1 portDS-3: 75-ohm coaxial

BNC, 2 or 4 T3 DS3 ports

E-3: 75-ohm coaxial BNC, 2 E3 ports

T1/E1 ATM trunk: RJ-48, 4 ports, balanced or unbalanced

T1/E1 circuit emulation: RJ-48, 4 ports, balanced or unbalanced

25 Mbps ATM: Telco cable 96-pin, 12 ATM25 ports

Duplex 10-Mbps Ethernet: Full or half duplex

100-Mbps Fast Ethernet: Full or half duplex

10/100-Mbps Fast Ethernet: Auto-negotiated speed and duplex

1000 Mbps Gigabit Ethernet: Full or half duplex

Token Ring copper: full or half duplex

Token Ring fiber: half duplex

FDDI: Half duplex

ATM: Full duplex

Group switched 10BaseT and 100BaseTX: Half duplex

Network Management CiscoWorks for Switched Internetworks GUI management including the following:

CiscoView

VlanDirector

Traffic Director

User Tracking

ATMDirector

Cisco Discovery Protocol

VLAN Trunk Protocol

SNMP agent v1 (RFC 1155-1157)

SNMP MIB II (RFC 1213)

RMON (4 groups)

RMON/RMON2 (all groups) with the opitonal Network Analysis Module (WS-X5380)

Ethernet MIB (RFC 1643)

Ethernet repeater MIB (RFC 1516)

Interface Table (RFC 1573)

Bridge MIB (RFC 1493)

Token Ring MIB (RFC 1748)

Source-Route Bridge MIB (RFC 1525)

Cisco Stack MIB Extensions (Token Ring group)

RMON Token Ring Extensions (RFC 1513)

Token Ring extensions for Statistics, History, Alarms, and Events groups

Ring Station Order Group

Ring Station Control Table

FDDI MIB (RFC 1512)

SMT 7.3 (RFC 1285)

AToM MIB (RFC 1695)

ILMI MIB

Cisco Workgroup MIB

LEC MIB (ATM Forum LANE v1.0)

Cisco LECS, LES/BUS MIB

Telnet, TFTP, BOOTP, LAN Emulation client, RFC 1577 Classical IP over ATM client: management access

Network Management (Continued) E-SPAN

Text-based command-line interface based on familiar router interface

Standard Cisco IOS security capabilities: passwords and TACACS

Standard protocols Ethernet: IEEE 802.3, 10BaseT, and 10BaseFL

Fast Ethernet: IEEE 802.3u, 100BaseTX, 100BaseFX

Gigabit Ethernet: IEEE 802.3z

Token Ring: IEEE 802.5r, IEEE 802.5j

FDDI: ISO 9314-1 FDDI PHY standard; ISO 9314-3 FDDI PMD standard; CDDI TP-PMD standard; ANSI FDDI X3T9.5 SMT 7.3

ATM: ATM Forum--3.1 UNI Specification, Q.2931 signaling protocols, ATM Forum LANE v1.0, LUNI v.2.0, MPOA

Maximum cabling distances 10BaseT Ethernet: Category 5 UTP, 328 ft (100 m)

10BaseFL Ethernet: 62.5/125-micron fiber, 1.24 miles (2 km)

100BaseTX Fast Ethernet: Category 5 UTP, 328 ft (100 m)

10/100BaseTX Fast Ethernet: Category 5 UTP, 328 ft (100 m)

100BaseFX Fast Ethernet: 62.5/125 multimode fiber, 0.248 mile (400 m) half duplex, 1.24 miles (2 km) full duplex or 8.7/125 single-mode fiber, 6.2 miles (10 km), full or half duplex

1000BaseSX Gigabit Ethernet: 62.5/125 MMF, 0.171 miles (275 m); 50/125 MMF, 0.341 miles (550m)

1000Base LX Gigabit Ethernet: 62.5/125 MMF, 0.341 miles (550m); 50/125 MMF, 0.341 miles (550m); 9/125 or 10/125 SMF, 6.2 miles (10km)

4-Mbps Token Ring 150-ohm STP: Types 1, 1a, 2, 2a, 2460 feet (750 m); Type 8, 1234 feet (376 m); Type 9, 1640 feet (500 m)

4-Mbps Token Ring 100-ohm UTP: Category 3, 820 feet (250 m); Category 4, 1148 feet (350 m); Category 5, 1148 feet (350 m)

16-Mbps Token Ring: 150-ohm STP Types 1, 1a, 2, 2a, 952 feet (290 m); Type 8, 480 feet (146 m); Type 9, 656 feet (200 m)

16-Mbps Token Ring 100-ohm UTP: Category 3, 328 feet (100 m); Category 4, 656 feet (200 m); Category 5, 656 feet (200 m)

CDDI: Category 5 UTP, 328 ft (100 m)

FDDI: 62.5/125 multimode fiber, 1.24 miles (2 km) or 8.7/125 single-mode fiber,

6.2 miles (10 km)

ATM LAN emulation module UTP: Category 5 UTP, 328 ft (100 m)

ATM Uplink module MMF: 62.5/125-micron fiber, 1.24 miles (2 km)

ATM Uplink module SMF: 8.7/125-micron fiber, 6.2 miles (10 km)

Fiber-optical specifications Multimode specifications for modules WS-X5006, WS-X5011,

WS-X5114=, WS-X5101, WS-X5158, WS-X5167,WS-X5031, and WS-X5506:

-Transmitter output power: -19 to -14 dBm

-Receiver sensitivity: -32.5 to -14 dBm

-Wavelength: 850 to 1360 nm

-Optical source: LED

-Maximum span: 1.24 miles (2 km)

Single-mode specifications for modules WS-X5005, WS-X5157, WS-X5168, WS-X5114=, WS-X5154, and WS-X5505:

-Transmitter output power: -14 to -8 dBm

-Receiver sensitivity: -32.5 to -8 dBm

-Wavelength: 1261 to 1360 nm

-Optical source: Laser

-Maximum span: 6.2 miles (10 km)

Single-mode specifications for module WS-X5104:

-Transmitter output power: -4.0 to-7.0 dBm

-Receiver sensitivity: -33 to -14 dBm

-Optical source: Laser

-Maximum span: 18.63 miles (30 km)

Fiber optical specifications for ASP port adapter modules and ATM OC-12 Uplink Module OC-12 multimode fiber PAM or OC-12 LANE/MPOA Uplink Module (WS-X5161):

-Transmitter output power: -20 to -14 dBm

-Receiver sensitivity: -26 to -14 dBm

-Wavelength: 1270 to 1380 nm

-Optical source: LED

-Maximum span: 500 m

OC-12 single-mode fiber IR PAM or ATM OC-12 LANE/MPOA Uplink Module (WS-X5162)

-Transmitter output power: -15 to -8 dBm

-Receiver sensitivity: -28 to -8 dBm

-Wavelength: 1260 to 1360 nm

-Optical source: Laser

-Maximum span: 15 km (intermediate reach)

OC-12 single-mode fiber LR PAM

-Transmitter output power: -3 to 2 dBm

-Receiver sensitivity: -28 to -8 dBm

-Wavelength: 1280 to 1335 nm

-Optical source: Laser

-Maximum span: 40 km (long reach)

OC-3 multimode fiber PAM

-Transmitter output power: -20 to -14 dBm

-Receiver sensitivity: -30 to -14 dBm

-Wavelength: 1270 to 1380 nm

-Optical source: LED

-Maximum span: 2 km

OC-3 single-mode fiber IR PAM

-Transmitter output power: -15 to -8 dBm

-Receiver sensitivity: -28 to -8 dBm

-Wavelength: 1260 to 1360 nm

-Optical source: Laser

-Maximum span: 15 km (intermediate reach)

OC-3 mixed-mode fiber IR+ PAM (For IR+ only - For MM specifications see OC-3 MM PAM above)

-Transmitter output power: -8 to -3 dBm

-Receiver sensitivity: -32 to -3 dBm

-Wavelength: 1270 to 1380 nm

-Optical source: Laser

-Maximum span: 30 km (intermediate reach plus)

OC-3 single-mode fiber LR PAM

-Transmitter output power: -5 to -0 dBm

-Receiver sensitivity: -34 to -10 dBm

-Wavelength: 1280 to 1335 nm

-Optical source: Laser

-Maximum span: 40 km (long reach)

LEDs Status LED on each module shows successful completion, minor and major failure of power-up diagnostics

Link Good LED shows status of any interface

Switch Load LEDs show backplane utilization

MII = media-independent interface

FE = Fast Ethernet

MMF = multimode fiber

SMF = single-mode fiber

dBm = decibels per milliwatt


Table 7-4: Catalyst 5000 Family Environmental Specifications

Characteristic Specification
Temperature Operating: 32°F to 104°F (0°C to 40°C)

Storage: -40°F to 167°F (-40°C to 75°C)

Humidity 10 to 90%, noncondensing
MTBF1 7 years for system configuration
Safety certifications UL 1950

EN 64950

CSA-C22.2 No. 950 93

IEC 950

Electromagnetic emissions certifications FCC 15J Class A

VCCI Class 2 on shielded UTP

CE Mark on shielded UTP

EN 55022A Class B on shielded UTP

CISPR 22 Class B

AC power requirements Catalyst 5500

8.0 Amps at 230 VAC2, 50 Hz

16 Amps at 115 VAC, 60 Hz

Power consumption: 1100W

kVA3 = 1.84

DC power requirements Catalyst 5500

-40.5 VDC4 to -72 VDC continuous

Typical range (U.S. and Canada)

-48 VDC (nominal)

-54 VDC (high)

-42 VDC (low)

Typical range (international)

-60 VDC (nominal)

-72 VDC (high)

-52 VDC (low)

Dimensions (H x W x D) Catalyst 5500

25.25 x 17.3 x 18.25 in.

(64.14 x 43.9 x 46.36 cm)

Weight Catalyst 5500

Minimum: 70 lb (31.7 kg)

Maximum: 160 lb (72.5 kg)

1. MTBF = mean time between failures

2. VAC = volts alternating current

3. kVA = kilovoltampere

. BTU = british thermal units

4. VDC = volts direct current



Note


Software

The following section describes software feature information for the Catalyst 5500 and 5000.

Bandwidth Management

Network Resiliency

VLANs

Embedded Manageability

Security Services

Enhanced Feature Set (Release 3.1 and higher)

Ordering Information

Configuration Worksheets

For configuration and wiring layout information for the Catalyst 5000 Family switches, access Cisco Online Connection (CCO) at the following URL:

http://www.cisco.com.

Product and Part Numbers

Table 7-5: Part Numbers for the Catalyst 5000 Family Part Numbers

Part Description Part Number
Catalyst 5500 chassis WS-C5500
Catalyst 5500 chassis with single AC power supply WS-C5507=
Catalyst 5500 single AC power supply WS-C5508
Catalyst 5500 second AC power supply WS-C5508/2
Catalyst 5500 single DC power supply WS-C5568
Catalyst 5500 second DC power supply WS-C5568/2
Catalyst 5500 rack-mount kit and cable organizer (spare) WS-C5599=
Catalyst 5500 fan tray (spare) WS-C5504=
Catalyst 5500 backplane clock module (spare) WC-C5505=
Catalyst 5500 RMON agent license WS-C5500-EMS-LIC
Catalyst 5500 SMARTnet maintenance See the "Service and Support" chapter.
Catalyst 5509 System  
   
Catalyst 5509 chassis WS-C5509
Catalyst 5509 chassis with single AC power supply WS-C5509-CHAC=
Catalyst 5509 Spare Chassis with one DC power supply WS-C5509-CHDC=
Catalyst 5509 AC Power Supply WS-C5518
Catalyst 5509 AC Power Supply (spare) WS-C5518=
Catalyst 5509 second AC Power Supply WS-C5518/2
Catalyst 5509 DC Power Supply WS-C5598
Catalyst 5509 DC Power Supply (spare) WS-C5598=
Catalyst 5509 second DC Power Supply WS-C5598/2
Catalyst 5509 Fan Tray (spare) WS-C5509-FAN=
Catalyst 5505/5509 Backplane Clock Module (spare) WS-C5514-CL=
Catalyst 5509 Rack Mount Kit and Cable Organizer WS-C5509-RACK=
Catalyst 5509 RMON Agent License WS-C5509-EMS-LIC
Catalyst 5509 SMARTnet maintenance CON-SNT-WS-C5509
   
   
Catalyst 5505 System  
   
Catalyst 5505 chassis WS-C5505
Catalyst 5505 chassis with single WS-C5008B AC power supply (spare) WS-C5505-CHAC=
Catalyst 5505 backplane clock module (spare) WS-C5505-CL=
Catalyst 5505 AC power supply WS-C5008B
Catalyst 5505 second AC power supply (spare) WS-C5008B/2
Catalyst 5505 RMON agent license WS-C5505-EMS-LIC
Catalyst 5505 SMARTnet maintenance CON-SNT-WS-C5505
Catalyst 5000 System  
   
Catalyst 5000 chassis WS-C5000
Catalyst 5000 chassis with single AC power supply (spare) WS-C5007=
Catalyst 5000 single AC power supply WS-C5008B
Catalyst 5000 second AC power supply (optional) WS-C5008B/2
Catalyst 5000 single DC power supply WS-C5068
Catalyst 5000 second DC power supply (optional) WS-C5068/2
Catalyst 5500 single AC power supply (optional) WS-C5008B
Catalyst 5500 second AC power supply (optional) WS-C5008B/2
Catalyst 5500 DC power supply WS-C5068B
Catalyst 5500 redundant DC power supply WS-C5068B/2
Catalyst 5000 rack-mount kit and cable organizer (spare) WS-C5099=
Catalyst 5000 RMON agent license WS-C5K-EMS-LIC
Catalyst 5000 Release 2.1 memory upgrade MEM-C5K-4M-V21
Catalyst 5000 Release 2.2 custom memory upgrade MEM-C5K-16M-Custom=
Catalyst 5000 Release 2.2 memory upgrade MEM-C5K-16M=
Catalyst 5000 series User Guide DOC-5000UG3=
Catalyst 5000 series Configuration Guide and Command Reference DOC-5000CGCR3=
Catalyst 5000 RMON Agent License WS-C5K-EMS-LIC
Catalyst 5000 SMARTnet maintenance CON-SNT-WS-C5001
Catalyst 5002 System  
Catalyst 5002 chassis (with integrated dual AC power supplies) WS-C5002
Catalyst 5002 chassis (with integrated dual DC power supplies) WS-C5002-DC
Catalyst 5002 RMON agent license WS-C5002-EMS-LIC
   
Catalyst 5002 SMARTnet maintenance CON-SNT-WS-C5002
Supervisor Engines  
   
Catalyst 5000/5002 supervisor engine I, 100BaseTX WS-X5009
Catalyst 5000/5002 supervisor engine I, 100BaseFX (SMF) WS-X5005
Catalyst 5000/5002 supervisor engine I, 100BaseFX (MMF) WS-X5006
Catalyst 5000/5002/5500 supervisor engine II, 100BaseTX and MII WS-X5509
Catalyst 5000/5002/5500 supervisor engine II, 100BaseFX (MMF) WS-X5506
Catalyst 5000/5002/5500 supervisor engine II, 100BaseFX (SMF) WS-X5505
Catalyst 5002/5000/5505/5500 supervisor engine III base module WS-X5530-E1
Catalyst 5000 24-port 10/100BaseTX Backbone Fast EtherChannel Switching Module (802.1Q/ISL, RJ-45) WS-X5225R
Catalyst 5000 24-port 10/100BaseTX Backbone Fast EtherChannel Switching Module (802.1Q/ISL, RJ-45) (spare) WS-X5225R=
Catalyst 5000 12-port 100BaseFX Backbone Fast EtherChannel Switching Module (802.1Q/ISL, SC) WS-X5201R
   
Catalyst 5000 12-port 100BaseFX Backbone Fast EtherChannel Switching Module (802.1Q/ISL, SC) (spare) WS-X5201R=
Catalyst 5000 3-port Gigabit Ethernet Switching Module w/out GBICs WS-X5403
Catalyst 5000 3-port Gigabit Ethernet Switching Module w/out GBICs (spare) WS-X5403=
Catalyst 5002/5000/5505/5500 Supervisor Engine III Base Module w/NFFC WS-X5530-E2
Catalyst 5002/5000/5505/5500 Supervisor Engine III Base Module w/NFFC (spare) WS-X5530-E2=
10BT Switched Ethernet 3 Pack of WS-X5012, 3x48 ports, Telco WS-X5012-3PACK
10BT Switched Ethernet 3 Pack of WS-X5012, 3x48 ports, Telco (spare) WS-X5012-3PACK=
10BT Switched Ethernet 3 Pack of WS-X5013, 3x24 ports, RJ-45 WS-X5013-3PACK
10BT Switched Ethernet 3 Pack of WS-X5013, 3x24 ports, RJ-45 (spare) WS-X5013-3PACK=
Fast Ethernet 10/100 3 Pack of WS-X5224, 3x24 ports, RJ-45 WS-X5224-3PACK
Fast Ethernet 10/100 3 Pack of WS-X5224, 3x24 ports, RJ-45 (spare) WS-X5224-3PACK=
Supervisor Engines  
   
Dual port 100BaseTX uplink module for supervisor III WS-U5531-FETX
Dual port 100BaseFX MMF uplink module for supervisor III WS-U5533-FEFX-MMF
Dual port 100BaseFX SMF uplink module for supervisor III WS-U5535-FEFX-SMF
Dual port 1000BaseSX Uplink module for Supervisor-3 WS-U5534-GESX
Dual port 1000BaseSX Uplink module for Supervisor-3 (spare) WS-U5534-GESX=
Interface Modules  
   
Catalyst 5500, 5000, and 5002  
   
C5K SW Flash for TR and ENET LANE for ATM dual phy module SFC5-TELANE100.1
C5K SW Flash for TR and ENET LANE for ATM dual phy module SWC5-TELANE100.1=
Catalyst 5000 ATM LANE module (UTP, RJ-45) WS-X5153
Catalyst 5000 ATM LANE module (single mode, SC) WS-X5154
Ethernet switching module (10BaseT, 24 , Telco) WS-X5010
Ethernet switching module (10BaseFL, 12 interfaces) WS-X5011
Desktop Ethernet Switching module (10BaseT, 48, Telco) WS-X5012
Ethernet switching module (10BaseT, 24 RJ-45) WS-X5013
Fast Ethernet 10/100 switching module (10/100 autonegotiating, 24, RJ-45) (No ISL) WS-X5224
Group Ethernet switching module (10BaseT, 48, Telco) WS-X5020
Fast Ethernet switching module (10/100BaseTX, autonegotiation, 12, RJ-45) (ISL every port.) WS-X5213A
Group switched 100BaseTX Ethernet (24, RJ-45) WS-X5223
Fast Ethernet switching module (100BaseFX, 12 ports MMF) WS-X5111
Fast Ethernet switching module (100BaseFX, 6 ports MMF, 6 ports SMF) WS-X5114
Fast Ethernet switching module with Fast EtherChannel (100BaseFX, 12, SC) WS-X5201
Fast Ethernet switching module with Fast EtherChannel (10/100BaseTX, 12, RJ 45)
WS-X5203  
Token Ring UTP/STP switching module (4/16 Mbps, 16 ports) WS-X5030
Token Ring fiber switching module (MMF, 16 ports) WS-X5031
CDDI module (UTP, RJ-45) WS-X5103
FDDI module (multimode, MIC) WS-X5101
FDDI module (single mode, ST) WS-X5104
ATM LAN Emulation module, dual PHY, UTP, WS-X5156
ATM LAN Emulation module, dual PHY, MMF SC WS-X5158
ATM LAN Emulation module, dual PHY, SMF SC WS-X5157
Route Switch Module (RSM) (Inter-VLAN Layer 3) WS-X5302
Network Analysis Module WS-X5380
NetFlow Feature Card (spare) WS-F5521=
Catalyst 5500 Only  
   
ASP (ATM Switch Processor plus feature card 1) L1010-ASP-B-FC1
DRAM Options for the ASP  
   
ASP DRAM 16-MB SIMM MEM-ASP-16M
ASP DRAM 32-MB SIMM MEM-ASP-32M
ASP DRAM 64-MB SIMM MEM-ASP-64M
Flash Memory Cards  
PCMCIA Flash memory card, 8 MB (spare) MEM-ASP-FLC8M=
PCMCIA Flash memory card, 16 MB (spare) MEM-ASP-FLC16M=
PCMCIA Flash memory card, 20 MB (spare) MEM-ASP-FLC20M=
Cisco/OS software for ATM feature set, version 11.2.2 SF-WAS3-11.2.2
Cisco/OS software for ATM feature set (spare) SW-WAS3-11.2.2=
Carrier Modules  
   
Carrier module for 2-port PAMs with slot covers for empty slots WATM-CAM-2P
CAM slot cover (spare) WATM-CAM-CVR=
PAM slot cover (spare) WAI-CVR=
Catalyst 5500 Port Adapter Modules  
ATM OC-3, 155-Mbps multimode fiber WAI-OC3-4MM
ATM OC-3, 155-Mbps single-mode fiber WAI-OC3-4SS
ATM OC-3, 155-Mbps unshielded twisted pair, Category 5 (UTP-5) WAI-OC3-4U5
ATM OC-12, 622-Mbps single-mode fiber WAI-OC12-1SS
DS-3 with 2 T3 ports, coaxial cable, BNC connectors WAI-T3-2BNC
E-3 with 2 ports, coaxial cable, BNC connectors WAI-E3-2BNC
E-3 with 4 ports, coaxial cable, BNC connectors WAI-E3-4BNC
T1 ATM trunk WAI-T1-4RJ48
E1 ATM trunk (balanced) WAI-E1-4RJ48
E1 ATM trunk (unbalanced) WAI-E1-4BNC
T1 circuit emulation WAI-T1C-4RJ48
E1 circuit emulation (balanced) WAI-E1C-4RJ48
E1 circuit emulation (unbalanced) WAI-E1C-4BNC
25-Mbps ATM WAI-ATM25-12P
1000BASE-SX "short wavelength" GBIC (multimode only) WS-G5484
1000BASE-SX "short wavelength" GBIC (multimode only) (spare) WS-G5484=
1000BASE-LH "long haul" GBIC (singlemode or multimode) WS-G5486
1000BASE-LH "long haul" GBIC (singlemode or multimode) (spare) WS-G5486=
Cisco IOS Software Feature Licenses  
   
Catalyst 5K Rel. 4.x SW License, Enhanced Feature Set SWC5K-BEFS-4X
Catalyst 5K Rel. 4.x SW License, Enhanced Feature Set (spare) SWC5K-BEFS-4X=
Catalyst 5K Rel. 4.x SW License, Enhanced Feature Set, upgrade SWC5K-BEFS-4X-UG
Route Switch Module  
   
Catalyst 5000 Switch Route Module WS-X5302
Catalyst 5000 Versatile Interface Processor-2 (VIP-2) Model 15 WS-X5303-15=
Catalyst 5000 Versatile Interface Processor-2 (VIP-2) Model 40 WS-X5303-40=
Catalyst 5000 RSM/VIP2-15 WS-X5304-15
Catalyst 5000 RSM/VIP2-40 WS-X5304-40
RSM console cable (spare) CAB-RSM2CON=
RSM auxiliary cable (spare) CAB-RSM2AUX=
RSM Flash Credit Card: 16 MB (default) MEM-RSM-FCL16M
RSM Flash Credit Card: 20 MB Option MEM-RSM-FCL20M
RSM 32-MB DRAM option (default) MEM-RSM-32M
RSM 64-MB DRAM option MEM-RSM-64M
RSM 128-MB DRAM option MEM-RSM-128
RSM NetFlow License (default) FR-NFC5
Cisco IOS Catalyst 5000 RSM WAN packet protocols license FRC5-WPP=
Cisco IOS Catalyst 5000 RSM NAT license FRC5-NAT
Cisco IOS Catalyst 5000 RSM IP with VIP feature set SFC5CV-11.2.9P
Cisco IOS Catalyst 5000 RSM desktop with VIP feature set SFC5BV-11.2.9P
Cisco IOS Catalyst 5000 RSM enterprise with VIP feature set SFC5AV-11.2.9P
CiscoWorks for Switched Internetworks (CWSI)  
   
CiscoWorks for switched Internetworks--IBM AIX CWSI-1.3-NV
CiscoWorks for switched Internetworks-IBM AIX upgrade CWSI-1.3-NV-UG
CiscoWorks for switched Internetworks--HP UX CWSI-1.3-OVH
CiscoWorks for switched Internetworks--HP UX upgrade CWSI-1.3-OVH-UG
CiscoWorks for switched Internetworks--Windows NT CWSI-1.3-WIN-NT
CiscoWorks for switched Internetworks--Windows NT upgrade CWSI-1.3-WIN-NT-UG
CiscoWorks for switched Internetworks--Solaris (HPOV and SNM) CWSI-1.3.1-SOLAR
CWSI-Solaris (HPOV and SNM)--upgrade CWSI-1.3.1-SOLAR-U
Cables  
   
Category 3 Telco Cable Assy. M90 to F90,5 "CAB-3-M90F90-5=
Category 3 Telco Cable Assy. M90 to F90, 10 "CAB-3-M90F90-10=
Category 3 Telco Cable Assy. M180 to F90, 5 "CAB-3-M180F90-5=
Category 3 Telco Cable Assy. M180 to F90, 10 "CAB-3-M180F90-10=
Category 3 Telco Cable Adapter (110 degrees) CAB-3-ADPTR-TEL=
ST Cable for Catalyst 5000 Fiber Token Ring module, 1 m WS-CAB01ST
ST Cable for Catalyst 5000 Fiber Token Ring module, 3m WS-CAB03ST
ST Cable for Catalyst 5000 Fiber Token Ring module, 8m WS-CAB08ST

Возврат на первую страницу
© TerraNet
webmaster@terranet.ru
Москва, ул. Балтийская дом 14, помещение "НИИ специальных полимеров и коррозии"
Тел: +7 (495) 787-52-90,155-43-37/29/43 факс: +7 (495) 155-43-37/29/43